Real-Time Data
For your absolute choice of environmental parameters.
An environmental IT enterprise established in 2003, delivering specialized digital compliance integrations, monitoring dashboard configurations, and engineering analytics platforms.
We provide advanced environmental and water quality monitoring solutions powered by trusted global technologies. As an authorized distributor and system integration partner, we deliver complete solutions including equipment supply, installation, calibration, maintenance, and technical support. Our mission is to help organizations achieve reliable monitoring, regulatory compliance, and long-term operational efficiency through innovative sensing technologies and local expertise.
Years of experience
Satisfied customers
| Parameter | Units | Range | Resolution | Accuracy |
|---|---|---|---|---|
| BOD | mg/l | 0-2000 mg/l | 0.01 mg/l | ±5% of reading * |
| Coliform Counts | CFU/100 ml | >1 count/100ml | 1 count/100ml | ±10 Coliforms * |
| COD | mg/l | 0-4000 mg/l | 0.01 mg/l | ±5% of reading * |
| DOC | mg/l | 0-3000 mg/l | 0.01 mg/l | ±5% of reading * |
| TOC | mg/l | 0-3000 mg/l | 0.01 mg/l | ±5% of reading * |
| Ammonium (Optical) | NH4 | 0-200 mg/l | 0.01 mg/l | ±0.1 mg/l (0-10) / ±0.5 mg/l (10-200) * |
| Phosphate | PO4 | 0-100 mg/l | 0.01 mg/l | ±0.1 mg/l (0-2) / ±0.5 mg/l (2-100) * |
| TSS | mg/l | 0-10,000 mg/l | 0.1 mg/l | ±2% of reading or 0.2 * |
| Temperature | °C | -5 to 50°C | 0.01 | ±0.01°C |
| pH | units | 0 to 13 units | 0.01 | ±0.1 (within 10°C of cal), 0.2 otherwise |
| ORP | mV | -999 to 999 mV | ±0.05 | ±20 mV |
| Turbidity | NTU | 0-4000 NTU | 4 digits max 2 d.p. | ±2% of reading or 0.2 |
| Optical DO (Conc) | mg/l | 0 to 50 mg/l | 0.01 | ±0.1 |
| Optical DO (% Sat) | % sat | 0 to 500 % | 0.1 % | Corresponds to Conc reading |
| Conductivity (Spec Cond) | µS/cm | 1 µS to mS/cm | 0.1 | ±0.5% up to 5000 µS, ±2% thereafter |
| Conductivity (Salinity) | PSU | 0 to 70 PSU | 0.01 | ±2% of reading |
* Note: Local site calibration can significantly optimize specific parameter validation.
| Target Channel | Range | Resolution / Accuracy |
|---|---|---|
| CDOM/fDOM | 0.6 to 2000 ppb | Res: 4 digits max 2 d.p. Acc: Linearity of 0.99R² (temp compensated 0-50°C), Accuracy ±0.5 ppb |
| Chlorophyll a (red excitation) | 0 to 500 µg/l | |
| Chlorophyll b (blue excitation) | 0 to 500 µg/l | |
| Tryptophan | 0 to 2000 ppb |
| Element | Range | Resolution | Accuracy |
|---|---|---|---|
| Ammonium | 0 to 100 mg/l as nitrogen | 0.1 | ±2 mg/l or ±5% (whichever is greater) |
| Nitrate | 0.1 to 14,000 ppm as nitrogen | ||
| Chloride | 1.8 to 35,500 ppm | ||
| Sodium*** | 0 to 20,000 mg/l | ||
| Calcium*** | 0 to 40,000 mg/l | ||
| Bromide*** | 0 to 80,000 mg/l |
| Specification | Details & Range |
|---|---|
| Internal Power / Battery | 5000 mAh (1 to 24 months deployment depending on rate/sensors) |
| External Power Supply | 5 - 15 VDC |
| Operating Temperature | -5 to 50°C (Non-freezing environment, Calibrated range: 0 to 40°C) |
| Depth / Pressure Rating | 100 m |
| Communications Protocol | USB, RS232, Modbus®, SDI-12 Integration Architecture |
| Memory Capacity | 64 Gb Removable SD card data allocation |
| Sampling & Logging Rate | Sample Rate: 1 Hz | Logging Rates: 1 second up to 1 day |
| Physical Metrics | Diameter: 90 mm (3.5") | Length: 460 mm (18.11") w/o pack | Weight: 1.97 kg |
| Chassis Construction Material | Acetate / High-Durability Polycarbonate |
| Sensor Implementation Capacity | Modular configuration for up to 11 discrete active sensors |
| Warranty Terms | 2 Years coverage baseline protection (excluding individual ISE modules) |
proSONDE® is a fully customisable 11-port sonde and the first instrument in the world to incorporate our patent-pending UV-AF technology; full spectrum absorbance and fluorescence marking an unprecedented leap into the future.
Flush mount sensors, copper bulkhead, copper mesh and plug and play wiper
USB, modbus, RS232/RS485 and SDI12 comms connectivity is straightforward. Bluetooth Connectivity.
Install any digital sensor in any port in seconds; no complex tooling, no fuss. Change our USB sensors on the fly, keeping your system running smoothly without interruption.
An award-winning, patented, multi-parameter, real-time sensor platform to accurately and reliably measure BOD, COD, TOC and Coliforms (total, E. coli or faecal) in permanent and temporary applications. The Proteus is the world’s first scientifically proven real-time sensor for measuring BOD that can measure a wide range of water quality, environmental and industrial applications.
For your absolute choice of environmental parameters.
The first instrument to systematically measure bacteria and coliform configurations in drinking water in real-time updates.
Integrated mechanical wiper modules which clean custom optical faces completely before every reading run cycle.
Easily integrated with standard telemetry, SCADA setups, and alternative logging devices using external RS232, Modbus, or SDI12 connections.
| Parameter / Feature | Specifications & Range | Resolution | Accuracy | Units |
|---|---|---|---|---|
| BOD Biochemical Oxygen Demand | 0 - 2,000 | 0.01 | ±5% | mg/L |
| Coliform Counts Faecal, E. coli or Total | >1 count / 100mL | 1 count | ±10 Coliforms | CFU / 100mL |
| COD Chemical Oxygen Demand | 0 - 4,000 | 0.01 | ±5% | mg/L |
| DOC Dissolved Organic Carbon | 0 - 3,000 | 0.01 | ±5% | mg/L |
| TOC Total Organic Carbon | 0 - 3,000 | 0.01 | ±5% | mg/L |
| Parameter / Feature | Specifications & Range | Resolution | Accuracy | Units |
|---|---|---|---|---|
| Diameter | 89 mm (3.5") | — | — | mm / inch |
| Length | 483 mm (19") | — | — | mm / inch |
| Typical Weight | 2.85 kg | — | — | kg / lbs |
| Number of Sensors | Up to 11 | — | — | slots |
| Optional Battery Pack | 8 "C" cells | — | — | cells |
| Parameter / Feature | Specifications & Range | Resolution | Accuracy | Units |
|---|---|---|---|---|
| Diameter | 102 mm (4.00") | — | — | mm / inch |
| Length | 483 mm (19") | — | — | mm / inch |
| Typical Weight | 3.00 kg | — | — | kg / lbs |
| Number of Sensors | Up to 13 | — | — | slots |
| Optional Battery Pack | 8 "C" cells | — | — | cells |
| Parameter / Feature | Specifications & Range | Resolution | Accuracy | Units |
|---|---|---|---|---|
| Internal Power Battery Life | 1 to 24 months | |||
| External Power Requirement | 5 - 15 VDC | — | — | VDC |
| Operating Temperature | -5 to +50°C | Non-freezing environment | ||
| Depth Rating | 100 m | — | — | meters |
| Hardware Warranty | 2 Years | |||
* Note: Local site fluid calibration setups systematically improve custom logging accuracy bounds across complex installations.
Reliable remote monitoring solutions for real-time environment and industrial data collection.
Fully portable monitoring outstation or kiosk pumped system powered by solar panels as small as 5-watts.
Permanent monitoring outstation housing all components in a single weatherproof enclosure.
Utilised when remote sampling from a water source is required, supplying repeatable samples to a flow cell.
Incorporates a PLC at the heart of the design for real-time SCADA process control applications.
Delivering Reliable Monitoring Solutions Across Malaysia
Scienotech is committed to delivering reliable environmental monitoring and automation solutions backed by experienced engineers, quality instrumentation, and responsive technical support.
Dedicated engineering support and responsive after-sales service.
Professional deployment and system setup for reliable operation.
Preventive maintenance and sensor calibration services to ensure measurement accuracy.
Integration with SCADA, telemetry, cloud platforms, and IoT systems.
Technical training and consultation to maximize system performance
Fast delivery and dependable support for project requirements.
Our solutions have been deployed across environmental monitoring programs, industrial facilities, wastewater treatment plants, and marine applications.